Bogen PCM-TIM Overhead Paging System Configuration

Updated: 01/16/2025

Objective

Configuring a Bogen PCM-TIM overhead paging system for 8x8 services.

Applies To

  • Bogen PCM-TIM overhead paging system (FXS Mode Only)

Procedure

You must connect the 8x8 adapter to a Tel Line (Version 1) or 90v NGT RNG (Version 2) port before configuring the Bogen PCM-TIM Overhead Paging System. Refer to the Bogen installation manuals.
There are two versions or Hardware revisions of the Bogen PCMTM. Refer to the images below step 3 to identify the revision being configured. Both of the images are FXS Only.

Settings

  1. Ensure that only DIP Switch 6 is ON Version 1.
  2. Ensure that DIP Switch is set to Station Version 2.
  3. Using the phone line or RJ11 cable, connect your 8x8 adapter to the Tel Line (v1) or 90v NGT RNG (V2) port.
Version 1 Version 2
Bogen_PCM_TIM_Paging_Config.png
PCMTIM2.jpg

Additional Information

There are three Bogen PCM models and differing version releases. Refer to Bogen Resource Library for more information.